Track manual or motorized single-axis scanner for ultrasonic inspection of annular welded joints made of non-magnetic and magnetic materials with diameters from 108 mm to 426 mm
The SK159-426 scanner is designed for ultrasonic inspection of annular welded joints of welding pipes of pipelines made of corrosion-resistant materials. The scanner is moved along the track installed on the control object. The scanner can be equipped with a second encoder (path sensor X) for manual scanning along the second axis.
Usage
Scanner control
Scanner control device
Scanners
Name | Article | Standard equipment |
Manual scanner SK159-426 |
S0160041 |
|
Motorized scanner SK159-426 |
S0160054 |
|
Tracks
If necessary, any number of tracks can be ordered additionally.
The track can be made to order with the required diameter.
Name | Article | Standard equipment |
Track ring 800 |
S0190006 |
Pipeline track 820 mm |
Track ring 600 |
S0220001 |
Pipeline track 630 mm |
Track ring 560 |
S0220002 |
Pipeline track 560 mm |
Track ring 990 |
S0220003 |
Pipeline track 990 mm |
Track ring 1020 |
S0220004 |
Pipeline track 1020 mm |
Track ring 1220 |
S0220005 |
Pipeline track 1220 mm |
Track ring 1420 |
S0220006 |
Pipeline track 1420 mm |
Track 159-219 | S0160049 | Track scanner for pipes Ø159-219 mm |
Track 245 | S0180004 | Track scanner for pipes Ø245 mm |
Track 273 | S0160050 | Track scanner for pipes Ø273 mm |
Track 325 | S0160051 | Track scanner for pipes Ø325 mm |
Track 377-426 | S0160052 | Track scanner for pipes Ø377-426 mm |
Clamps
Name | Article |
ПР-АР-В-По-Вт-РШ |
S021009 |
Manual scanner![]() |
Motorized scanner![]() |
Specifications
Range of inspection pipe diameters | from 159 to 426 mm |
Moving along the track that is installed on the control object | |
The motorized scanner is equipped with a control unit for automated movement with speed and direction adjustment | |
The scanner is equipped with a clamp that ensures optimal contact with the control surface at any position and orientation of the scanner | |
The scanner is equipped with a clamp for checking for transverse defects | |
Width of the clamp fork for mounting the converter with a prism | 30 mm |
Carriage length | 110 mm |
Carriage stroke length | 87 mm |
Dimensions, L x W x H |
279 х 79 х 264 mm |
Weight (without track) | 1,8-1,9 kg |
Encoder resolution | 4,8 counts / mm |